Model 86984 Hydrogen Booster

Double-Acting, Single Stage HYDROGEN Booster

See this product on the NEW Fluid Process Control website!

Description

Haskel Model 86984 Air-Driven Hydrogen Gas Booster

Catalog literature: Gas Booster Catalog.pdf Acrobat DC

NOTE: this is a version of the model AGD-30 Gas Booster modified for HYDROGEN service.

Features & Benefits:

  • Reliable, easy to maintain, compact and robust
  • No heat, flame or spark risk
  • Infinitely variable cycling speed and output
  • No electrical connections required
  • Easy to apply automatic controls
  • No limit or adverse affect to continuous stop/start applications
  • Seal systems designed for long working life
  • No air line lubricator required
  • Suitable for most gases
  • Ability to stall at any predetermined pressure and hold the fixed pressure without consuming power or generating heat

Technical Data:

  • BASE BOOSTER MODEL: AGD-30
  • 1st Stage Ratio: -30
  • 2nd Stage Ratio: N/A
  • Min HYDROGEN supply pressure: 100 psi
  • Max HYDROGEN supply pressure: 9000 psi
  • Max rated HYDROGEN outlet pressure: 9000 psi
  • Static outlet stall pressure formula: 30 Pa + Ps (Pa = air drive pressure, Ps = GAS supply pressure)
  • Min AIR drive pressure: 20 psi
  • Max AIR drive pressure: 150 psi

Sample Performance Characteristics:

  • Boost 9.6 SCFM Gas from 850 psi to 2800 psi while using 40 SCFM Air @ 90 psig supply pressure
  • Boost 19 SCFM Gas from 1550 psi to 3200 psi while using 40 SCFM Air @ 90 psig supply pressure
  • Boost 25.5 SCFM Gas from 2250 psi to 4200 psi while using 40 SCFM Air @ 90 psig supply pressure
  • Boost 35.6 SCFM Gas from 2850 psi to 4200 psi while using 40 SCFM Air @ 90 psig supply pressure

Physical Characteristics:

  • Unit weight: 38 LBS.
  • Displacement / cycle: 6.2 cu. in.
  • Max cycles: 60/min.
  • GAS inlet/outlet connections: Interchangeable 3/8″ SAE or 1/4″ HP (2 inlet & 2 outlet)
  • AIR drive inlet port: 1/2″ FNPT