Double-Acting, Single Stage HYDROGEN Booster
See this product on the NEW Fluid Process Control website!
Description
Haskel Model 86984 Air-Driven Hydrogen Gas Booster
Catalog literature: Gas Booster Catalog.pdf
NOTE: this is a version of the model AGD-30 Gas Booster modified for HYDROGEN service.
Features & Benefits:
- Reliable, easy to maintain, compact and robust
- No heat, flame or spark risk
- Infinitely variable cycling speed and output
- No electrical connections required
- Easy to apply automatic controls
- No limit or adverse affect to continuous stop/start applications
- Seal systems designed for long working life
- No air line lubricator required
- Suitable for most gases
- Ability to stall at any predetermined pressure and hold the fixed pressure without consuming power or generating heat
Technical Data:
- BASE BOOSTER MODEL: AGD-30
- 1st Stage Ratio: -30
- 2nd Stage Ratio: N/A
- Min HYDROGEN supply pressure: 100 psi
- Max HYDROGEN supply pressure: 9000 psi
- Max rated HYDROGEN outlet pressure: 9000 psi
- Static outlet stall pressure formula: 30 Pa + Ps (Pa = air drive pressure, Ps = GAS supply pressure)
- Min AIR drive pressure: 20 psi
- Max AIR drive pressure: 150 psi
Sample Performance Characteristics:
- Boost 9.6 SCFM Gas from 850 psi to 2800 psi while using 40 SCFM Air @ 90 psig supply pressure
- Boost 19 SCFM Gas from 1550 psi to 3200 psi while using 40 SCFM Air @ 90 psig supply pressure
- Boost 25.5 SCFM Gas from 2250 psi to 4200 psi while using 40 SCFM Air @ 90 psig supply pressure
- Boost 35.6 SCFM Gas from 2850 psi to 4200 psi while using 40 SCFM Air @ 90 psig supply pressure
Physical Characteristics:
- Unit weight: 38 LBS.
- Displacement / cycle: 6.2 cu. in.
- Max cycles: 60/min.
- GAS inlet/outlet connections: Interchangeable 3/8″ SAE or 1/4″ HP (2 inlet & 2 outlet)
- AIR drive inlet port: 1/2″ FNPT