Single-Acting, Single Stage HYDROGEN Booster
See this product on the NEW Fluid Process Control website!
Description
Haskel Model 86979 Air-Driven Hydrogen Gas Booster
Catalog literature: Gas Booster Catalog.pdf
NOTE: this is a version of the model AG-62 Gas Booster modified for HYDROGEN service.
Features & Benefits:
- Reliable, easy to maintain, compact and robust
- No heat, flame or spark risk
- Infinitely variable cycling speed and output
- No electrical connections required
- Easy to apply automatic controls
- No limit or adverse affect to continuous stop/start applications
- Seal systems designed for long working life
- No air line lubricator required
- Suitable for most gases
- Ability to stall at any predetermined pressure and hold the fixed pressure without consuming power or generating heat
Technical Data:
- BASE BOOSTER MODEL: AG-62
- 1st Stage Ratio: -62
- 2nd Stage Ratio: N/A
- Min HYDROGEN supply pressure: 200 psi
- Max HYDROGEN supply pressure: 9000 psi
- Max rated HYDROGEN outlet pressure: 9000 psi
- Static outlet stall pressure formula: 60 Pa (Pa = air drive pressure, Ps = GAS supply pressure)
- Min AIR drive pressure: 20 psi
- Max AIR drive pressure: 150 psi
Sample Performance Characteristics:
- Boost 1.75 SCFM Gas from 500 psi to 4750 psi while using 30 SCFM Air @ 90 psig supply pressure
- Boost 3 SCFM Gas from 1000 psi to 4750 psi while using 30 SCFM Air @ 90 psig supply pressure
- Boost 5 SCFM Gas from 1500 psi to 4750 psi while using 30 SCFM Air @ 90 psig supply pressure
- Boost 6.5 SCFM Gas from 2000 psi to 4750 psi while using 30 SCFM Air @ 90 psig supply pressure
Physical Characteristics:
- Unit weight: 35 LBS.
- Displacement / cycle: 3.1 cu. in.
- Max cycles: 60/min.
- GAS inlet/outlet connections: Interchangeable 3/8″ SAE or 1/4″ HP
- AIR drive inlet port: 1/2″ FNPT