Model 87083 Hydrogen Booster

Single-Acting, Single Stage HYDROGEN Booster

See this product on the NEW Fluid Process Control website!

Description

Haskel Model 87083 Air-Driven Hydrogen Gas Booster

Catalog literature: Gas Booster Catalog.pdf Acrobat DC

 

NOTE: this is a version of the model AG-30 Gas Booster modified for HYDROGEN service.

Features & Benefits:

  • Reliable, easy to maintain, compact and robust
  • No heat, flame or spark risk
  • Infinitely variable cycling speed and output
  • No electrical connections required
  • Easy to apply automatic controls
  • No limit or adverse affect to continuous stop/start applications
  • Seal systems designed for long working life
  • No air line lubricator required
  • Suitable for most gases
  • Ability to stall at any predetermined pressure and hold the fixed pressure without consuming power or generating heat

Technical Data:

  • BASE BOOSTER MODEL: AG-30
  • 1st Stage Ratio: -30
  • 2nd Stage Ratio: N/A
  • Min HYDROGEN supply pressure: 100 psi
  • Max HYDROGEN supply pressure: 4500 psi
  • Max rated HYDROGEN outlet pressure: 4500 psi
  • Static outlet stall pressure formula: 30 Pa (Pa = air drive pressure, Ps = GAS supply pressure)
  • Min AIR drive pressure: 20 psi
  • Max AIR drive pressure: 150 psi

Sample Performance Characteristics:

  • Boost 2 SCFM Gas from 300 psi to 2200 psi while using 40 SCFM Air @ 90 psig supply pressure
  • Boost 4 SCFM Gas from 600 psi to 2200 psi while using 40 SCFM Air @ 90 psig supply pressure
  • Boost 6 SCFM Gas from 900 psi to 2200 psi while using 40 SCFM Air @ 90 psig supply pressure
  • Boost 8 SCFM Gas from 1200 psi to 2200 psi while using 40 SCFM Air @ 90 psig supply pressure

Physical Characteristics:

  • Unit weight: 27 LBS.
  • Displacement / cycle: 3.1 cu. in.
  • Max cycles: 60/min.
  • GAS inlet/outlet connections: Interchangeable 3/8″ SAE or 1/4″ HP
  • AIR drive inlet port: 1/2″ FNPT