Model 86990 Hydrogen Booster

Two Stage HYDROGEN Booster

See this product on the NEW Fluid Process Control website!

Description

Haskel Model 86990 Air-Driven Hydrogen Gas Booster

Catalog literature: Gas Booster Catalog.pdf Acrobat DC

NOTE: this is a version of the model AGT-7/30 Gas Booster modified for HYDROGEN service.

Features & Benefits:

  • Reliable, easy to maintain, compact and robust
  • No heat, flame or spark risk
  • Infinitely variable cycling speed and output
  • No electrical connections required
  • Easy to apply automatic controls
  • No limit or adverse affect to continuous stop/start applications
  • Seal systems designed for long working life
  • No air line lubricator required
  • Suitable for most gases
  • Ability to stall at any predetermined pressure and hold the fixed pressure without consuming power or generating heat

Technical Data:

  • BASE BOOSTER MODEL: AGT-7/30
  • 1st Stage Ratio: -7
  • 2nd Stage Ratio: -30
  • Min HYDROGEN supply pressure: 25 psi
  • Max HYDROGEN supply pressure: 2 Pa to 2500 psi
  • Max rated HYDROGEN outlet pressure: 9000 psi
  • Static outlet stall pressure formula: 30 Pa + 4 Ps (Pa = air drive pressure, Ps = GAS supply pressure)
  • Min AIR drive pressure: 20 psi
  • Max AIR drive pressure: 150 psi

Sample Performance Characteristics:

  • Boost 1.2 SCFM Gas from 50 psi to 2000 psi while using 40 SCFM Air @ 90 psig supply pressure
  • Boost 1.9 SCFM Gas from 75 psi to 2000 psi while using 40 SCFM Air @ 90 psig supply pressure
  • Boost 2.3 SCFM Gas from 100 psi to 2500 psi while using 40 SCFM Air @ 90 psig supply pressure
  • Boost 2.6 SCFM Gas from 150 psi to 3000 psi while using 32 SCFM Air @ 90 psig supply pressure

Physical Characteristics:

  • Unit weight: 41 LBS.
  • Displacement / cycle: 13.2 cu. in.
  • Max cycles: 60/min.
  • GAS inlet/outlet connections: 3/8″ FNPT inlet & Interchangeable 3/8″ SAE or 1/4″ HP outlet
  • AIR drive inlet port: 1/2″ FNPT