Model 86987 Hydrogen Booster

Double-Acting, Single Stage HYDROGEN Booster

See this product on the NEW Fluid Process Control website!

Description

Haskel Model 86987 Air-Driven Hydrogen Gas Booster

Catalog literature: Gas Booster Catalog.pdf Acrobat DC

NOTE: this is a version of the model AGD-75 Gas Booster modified for HYDROGEN service.

Features & Benefits:

  • Reliable, easy to maintain, compact and robust
  • No heat, flame or spark risk
  • Infinitely variable cycling speed and output
  • No electrical connections required
  • Easy to apply automatic controls
  • No limit or adverse affect to continuous stop/start applications
  • Seal systems designed for long working life
  • No air line lubricator required
  • Suitable for most gases
  • Ability to stall at any predetermined pressure and hold the fixed pressure without consuming power or generating heat

Technical Data:

  • BASE BOOSTER MODEL: AGD-75
  • 1st Stage Ratio: -75
  • 2nd Stage Ratio: N/A
  • Min HYDROGEN supply pressure: 250 psi
  • Max HYDROGEN supply pressure: 12,000 psi
  • Max rated HYDROGEN outlet pressure: 15,000 psi
  • Static outlet stall pressure formula: 75 Pa + Ps (Pa = air drive pressure, Ps = GAS supply pressure)
  • Min AIR drive pressure: 20 psi
  • Max AIR drive pressure: 150 psi

Sample Performance Characteristics:

  • Boost 5.5 SCFM Gas from 1000 psi to 5000 psi while using 50 SCFM Air @ 90 psig supply pressure
  • Boost 11.3 SCFM Gas from 2000 psi to 6000 psi while using 50 SCFM Air @ 90 psig supply pressure
  • Boost 14.3 SCFM Gas from 3000 psi to 8000 psi while using 45 SCFM Air @ 90 psig supply pressure
  • Boost 21.5 SCFM Gas from 5000 psi to 10000 psi while using 45 SCFM Air @ 90 psig supply pressure

Physical Characteristics:

  • Unit weight: 39 LBS.
  • Displacement / cycle: 2.4 cu. in.
  • Max cycles: 60/min.
  • GAS inlet/outlet connections: Interchangeable 3/8″ SAE or 1/4″ HP (2 inlet & 2 outlet)
  • AIR drive inlet port: 1/2″ FNPT