Double-Acting, Single Stage HYDROGEN Booster
See this product on the NEW Fluid Process Control website!
Description
Haskel Model 86982 Air-Driven Hydrogen Gas Booster
Catalog literature: Gas Booster Catalog.pdf
NOTE: this is a version of the model AGD-7 Gas Booster modified for HYDROGEN service.
Features & Benefits:
- Reliable, easy to maintain, compact and robust
- No heat, flame or spark risk
- Infinitely variable cycling speed and output
- No electrical connections required
- Easy to apply automatic controls
- No limit or adverse affect to continuous stop/start applications
- Seal systems designed for long working life
- No air line lubricator required
- Suitable for most gases
- Ability to stall at any predetermined pressure and hold the fixed pressure without consuming power or generating heat
Technical Data:
- BASE BOOSTER MODEL: AGD-7
- 1st Stage Ratio: -7
- 2nd Stage Ratio: N/A
- Min HYDROGEN supply pressure: 25 psi
- Max HYDROGEN supply pressure: 2500 psi
- Max rated HYDROGEN outlet pressure: 2500 psi
- Static outlet stall pressure formula: 7 Pa + Ps (Pa = air drive pressure, Ps = GAS supply pressure)
- Min AIR drive pressure: 20 psi
- Max AIR drive pressure: 150 psi
Sample Performance Characteristics:
- Boost 4 SCFM Gas from 100 psi to 500 psi while using 30 SCFM Air @ 90 psig supply pressure
- Boost 11.2 SCFM Gas from 300 psi to 800 psi while using 30 SCFM Air @ 90 psig supply pressure
- Boost 18.8 SCFM Gas from 500 psi to 1000 psi while using 30 SCFM Air @ 90 psig supply pressure
- Boost 16 SCFM Gas from 700 psi to 1300 psi while using 30 SCFM Air @ 90 psig supply pressure
Physical Characteristics:
- Unit weight: 35 LBS.
- Displacement / cycle: 26.4 cu. in.
- Max cycles: 60/min.
- GAS inlet/outlet connections: 3/8″ FNPT (2 inlet & 2 outlet)
- AIR drive inlet port: 1/2″ FNPT