83007

Two Stage HYDROGEN Booster

Description

Catalog literature: Gas Booster Catalog.pdf Acrobat DC

Features & Benefits:

  • Reliable, easy to maintain, compact and robust
  • No heat, flame or spark risk
  • Infinitely variable cycling speed and output
  • No electrical connections required
  • Easy to apply automatic controls
  • No limit or adverse affect to continuous stop/start applications
  • Seal systems designed for long working life
  • No air line lubricator required
  • Suitable for most gases
  • Ability to stall at any predetermined pressure and hold the fixed pressure without consuming power or generating heat

Technical Data:

  • BASE BOOSTER MODEL: AGT-14/62
  • 1st Stage Ratio: -14
  • 2nd Stage Ratio: -62
  • Min HYDROGEN supply pressure: 25 psi
  • Max HYDROGEN supply pressure: 4 Pa to 2500 psi
  • Max rated HYDROGEN outlet pressure: 9000 psi
  • Static outlet stall pressure formula: 60 Pa + 4 Ps (Pa = air drive pressure, Ps = GAS supply pressure)
  • Min AIR drive pressure: 20 psi
  • Max AIR drive pressure: 150 psi

Sample Performance Characteristics:

  • Boost 2.4 SCFM Gas from 125 psi to 4000 psi while using 58 SCFM Air @ 90 psig supply pressure
  • Boost 2.6 SCFM Gas from 175 psi to 4000 psi while using 54 SCFM Air @ 90 psig supply pressure
  • Boost 4.2 SCFM Gas from 275 psi to 5000 psi while using 56 SCFM Air @ 90 psig supply pressure
  • Boost 5 SCFM Gas from 350 psi to 6000 psi while using 54 SCFM Air @ 90 psig supply pressure

Physical Characteristics:

  • Unit weight: 41 LBS.
  • Displacement / cycle: 13.2 cu. in.
  • Max cycles: 60/min.
  • GAS inlet/outlet connections: 3/8″ FNPT inlet & Interchangeable 3/8″ SAE or 1/4″ HP outlet
  • AIR drive inlet port: 1/2″ FNPT